CSI DIVISION 26 24 13 1,200A–4,000A+ • 480Y/277V • UL 891 / UL 1558

Commercial Switchgear, Busduct & Underground Duct Bank Engineering

Electrical Dynamics, Inc. engineers, rigs, and commissions heavy 480Y/277V and 208Y/120V primary service entrances, multi-section switchboards (1,200A–4,000A+), industrial plug-in busways, and concrete-encased underground utility duct banks for biotech campuses, R&D facilities, and manufacturing plants across Massachusetts and Southern New Hampshire.

Service Ratings
1,200A – 4,000A+ @ 480Y/277V
Standards
UL 891, UL 1558, NEC Art. 230/408
OEM Platforms
Eaton, Square D, Siemens, ABB/GE
Utility Coordination
Eversource, National Grid, RMLD
CALL (978) 664-1050
Commercial Switchgear, Busduct & Underground Duct Bank Engineering
Authentic EDI Installation MA #13881A • NH #56C

Turnkey 480Y/277V Main Switchgear & Double-Ended Substations

Modern life-science laboratories, additive manufacturing facilities, and enterprise corporate campuses require high-fault-current-rated main service switchgear engineered for selective coordination and zero unplanned downtime. As an Eaton Certified Contractor with 35 Years of field execution, EDI manages long-lead switchgear procurement, rigging, housekeeping pad layout, ground-fault protection of equipment (GFPE per NEC 230.95), and Arc Energy Reduction (NEC 240.87) commissioning.

  • 1,200A, 2,000A, 3,000A, and 4,000A+ UL 891 Dead-Front Switchboards and UL 1558 Metal-Enclosed Low-Voltage Power Circuit Breaker Switchgear.
  • 65 kAIC to 100 kAIC symmetrical short-circuit current ratings (SCCR) with electronic trip units (LSIG) and Zone Selective Interlocking (ZSI).
  • Maintenance Mode (Energy-Reducing Maintenance Switching) and arc-flash boundary labeling per NFPA 70E and IEEE 1584.
  • Revenue-grade utility CT/PT metering cabinets built to Eversource Electric Information & Requirements (EIR), National Grid ESB 750, and municipal light department standards.

Concrete-Encased Underground Utility Duct Banks & Primary Vaults

From our multi-conduit duct bank installation at 400 Wheeler Road in Burlington to multi-building corporate campuses in Natick and Framingham, EDI self-performs trench layout, spacer-rack assembly, mandrel testing, and high-tension cable pulling between utility pole risers, precast manholes, pad-mounted transformers, and interior main switchgear rooms.

  • Multi-way 4" to 6" Schedule 40 / Schedule 80 PVC and fiberglass (FRE) duct banks with rebar reinforcement and red-dyed concrete encasement.
  • Long-radius rigid galvanized steel (RGS) and PVC-coated Robroy sweeps to eliminate cable jacket sidewall pressure during high-tension winch pulls.
  • Precast utility transformer pads, oil-containment grounding grids (counterpoise rings and exothermic Cadweld bonds), and primary/secondary pull boxes.
  • Mandrel proving, duct swabbing, and Megger insulation-resistance testing (1,000V DC) prior to utility energization.

High-Amperage Industrial Feeder & Plug-In Busduct Replacements

For high-density manufacturing plants and flexible R&D bays—such as our high-amperage busduct replacement for Sekisui Voltek in Lawrence and overhead trapeze racks at Desktop Metal in Burlington—overhead busway systems deliver superior voltage-drop performance and modular plug-in tap flexibility.

  • 400A to 4,000A copper and aluminum feeder busway and plug-in busduct risers.
  • Phased weekend/overnight live plant cutovers utilizing temporary generator power to eliminate manufacturing downtime.
  • Baseline FLIR infrared thermographic scanning and calibrated torque-seal verification on every busbar splice joint.

CSI Division 26 Switchgear & Feeder Engineering Matrix

SubsystemTechnical SpecificationApplicable Code / StandardEDI Field Deliverable
Main Service Switchgear1,200A–4,000A, 480Y/277V 3Ø 4W, 65–100 kAICNEC Art. 230 & 408 / UL 891 & 1558Pad layout, rigging, LSIG trip setup & Megger report
Arc Energy ReductionMaintenance switch (ERMS), ZSI, or differential relayNEC 240.87 / 527 CMR 12.00 / NFPA 70EVerified trip-time testing & permanent arc-flash labels
Underground Duct Banks4"–6" Sch. 40/80 PVC in 3,000+ PSI concrete envelopeNEC Art. 300.5 / NESC / Utility EIRSurveyed trenching, mandrel test & parallel Cu/Al pulls
Industrial Busduct800A–3,000A overhead feeder & fusible/breaker bus plugsNEC Art. 368 / NEMA BU 1Laser-aligned seismic trapeze hangers & IR baseline scan