Enterprise Card Access Control, Cleanroom Airlocks, IP Video Surveillance & Boardroom A/V
Because Electrical Dynamics holds both Massachusetts Master Electrical licensing (#13881A), UL Fire Alarm credentials, and BICSI Network Systems expertise, our teams deliver seamless physical security and audio/visual integrations—handling everything from 120V power supplies and electrified door hardware to FACP emergency drop-out relays and PoE network switching.
Enterprise Access Control, Electrified Door Hardware & Cleanroom Mantrap Interlocks
In biotech facilities, GMP manufacturing plants, and corporate headquarters, physical access control must satisfy strict FDA/DEA audit trails while complying with Massachusetts Building Code (780 CMR 1010) egress life-safety rules.
- OSDP v2 encrypted smart-card and mobile-credential readers, biometric scanners, electric strikes, mortise locks, and delayed-egress electromagnetic locks.
- Multi-door cleanroom airlock and mantrap sequencing with status indicators, emergency pull releases, and direct NFPA 72 Fire Alarm Control Panel relay drop-out.
- Altronix / LifeSafety Power networked power-supply enclosures with supervised battery backup and fire-alarm trigger disconnects.
NDAA-Compliant IP Video Surveillance (CCTV) & Executive Boardroom A/V
As demonstrated in our executive boardroom and lobby buildout for Quanterix Corporation in Billerica, EDI Network Systems integrates architectural A/V, conference room table connectivity boxes, and facility-wide IP security cameras.
- Indoor/outdoor PoE+ 4K dome, bullet, PTZ, and 180°/360° multi-sensor panoramic IP cameras covering loading docks, parking lots, lab corridors, and lobbies.
- Executive boardroom 4K display power/data backing, motorized shade integration, ceiling microphone arrays, and network-based sound masking systems.
Integrated Security, Access Control & A/V Infrastructure Scope
| System | Technical Specification | Code / Compliance Integration | Single-Source EDI Advantage |
|---|---|---|---|
| Card Access & Biometrics | OSDP v2 encrypted readers, PoE/RS-485 intelligent door controllers | UL 294 / NFPA 101 Delayed & Controlled Egress | 120V power, door hardware wiring & FACP relay by one contractor |
| Cleanroom Airlocks / Mantraps | 2-to-4 door interlocked PLC/controller logic with status strobes | Automatic fail-safe unlock on Fire Alarm activation | Zero finger-pointing between electrician, security & fire alarm vendor |
| IP Video Surveillance (CCTV) | NDAA-compliant PoE+ cameras, NVR storage & PoE surge arrestors | Bucket-truck exterior pole/parapet mounting | Complete Cat6A/Fiber backbone + exterior aerial mounting |
| Boardroom A/V & Sound Masking | Floor core pokes, table cubbies, display backing & plenum emitters | NEC Art. 640 / 725 Class 2 Plenum Compliance | Coordinated with architectural lighting & acoustic ceiling grids |
Submit Specifications — Enterprise Card Access Control, Cleanroom Airlocks, IP Video Surveillance & Boardroom A/V
Direct routing to Electrical Dynamics Estimating (info@electricaldynamics.com), 24/7 Service & Fire Alarm (service@electricaldynamics.com), or EDI Network Systems (telecom@electricaldynamics.com).