BICSI Structured Cabling, Single-Mode / OM4 Fiber Optic Splicing & MDF/IDF Buildouts
EDI Network Systems is the dedicated low-voltage and telecommunications engineering division of Electrical Dynamics, Inc. (telecom@electricaldynamics.com). As an accredited BICSI Corporate Member, we engineer, install, splice, and certify high-density copper and fiber optic network infrastructure for multi-building corporate campuses, biotech laboratories, and enterprise data centers across Greater Boston.
OS2 Single-Mode & OM4/OM5 Laser-Optimized Multimode Fiber Optic Backbones
From campus inter-building underground duct banks at The MathWorks (Apple Hill West) to multi-story riser backbones at Cumberland Farms’ 85,000 sq. ft. headquarters and Quanterix’s Billerica labs, EDI Network Systems executes precision ribbon and loose-tube fiber optic installations.
- Core-alignment fusion splicing with splice-on LC/APC and MPO/MTP high-density cassette terminations (<0.05 dB typical splice loss).
- Indoor/outdoor plenum-rated (OFNP) interlocking armored fiber and underground gel-free OSP campus duct bank fiber.
- Tier-1 (OLTS optical loss/length/polarity) and Tier-2 (bi-directional OTDR backscatter signature trace) certification at 850/1300 nm and 1310/1550 nm.
10-Gigabit Cat6A Shielded/UTP Horizontal Cabling & MDF/IDF Server Room Buildouts
Modern Wi-Fi 7 access points, PoE++ lighting/sensors, and high-throughput laboratory imaging workstations require ANSI/TIA-568.2-D compliant Category 6A cabling installed with strict bend-radius and EMI separation from 480V power raceways.
- 2-Post and 4-Post seismic equipment racks, acoustic server cabinets, overhead ladder racks, and basket-style wire mesh cable trays (CSI 27 05 29).
- ANSI/TIA-607-D telecommunications main grounding busbars (TMGB / TGB) bonded directly to building structural steel and main electrical service ground.
- 100% channel and permanent-link Fluke Versiv DSX-8000 certification reports backed by 25-Year Extended Manufacturer System Warranties (Legrand/Ortronics, Siemon, Belden, CommScope, Corning, Berk-Tek/Leviton).
CSI Division 27 Structured Cabling & Fiber Certification Standards
| Media Tier | Standard / Specification | Bandwidth / Application | Certification Deliverable |
|---|---|---|---|
| OS2 Single-Mode Fiber | ITU-T G.652.D / G.657.A1 (OFNP / Armored) | 10G / 40G / 100G / 400G Campus & Riser | Bi-directional OTDR trace & OLTS dB budget report (1310/1550 nm) |
| OM4 / OM5 Multimode Fiber | TIA-492AAAD / Wideband MMF (Aqua / Lime) | 10G / 40G / 100G Data Center & IDF Tie | Encircled Flux OLTS & MPO/LC end-face fiber inspection scope |
| Category 6A (F/UTP & UTP) | ANSI/TIA-568.2-D (500 MHz Alien Crosstalk) | 10GBASE-T, Wi-Fi 6E/7 APs & 90W PoE++ | Fluke DSX-8000 Permanent Link PDF & LinkWare native files |
| MDF / IDF Grounding | ANSI/TIA-607-D Telecommunications Bonding | Equipotential rack, tray & surge bonding | Exothermic/2-hole compression lug torque & resistance verification |
Submit Specifications — BICSI Structured Cabling, Single-Mode / OM4 Fiber Optic Splicing & MDF/IDF Buildouts